会社ニュース Does acridine ester labeling always fail? Mastering these key points can easily improve detection efficiency

Does acridine ester labeling always fail? Mastering these key points can easily improve detection efficiency

2025-12-31
Does acridine ester labeling always fail? Mastering these key points can easily improve detection efficiency

In chemiluminescence immunoassay, acridine ester is widely used as a core labeling reagent in the fields of disease diagnosis, biological research, and drug development due to its high sensitivity, low background interference, and rapid luminescence characteristics. However, many users often encounter issues of low efficiency, unstable signals, or even complete failure during the tagging process. This is not accidental, but rather due to a lack of understanding of the chemical properties of acridine esters or negligence in operational details. This article will analyze common reasons for system failures and provide practical solutions to help you optimize the tagging process and improve the success rate of experiments.


1, Understanding the characteristics of acridine esters: the basis for successful labeling


Acridine ester is an efficient chemiluminescent substrate, and the active ester groups in its structure can covalently bind with the primary amino groups of proteins, antibodies, or other biomolecules to form stable markers. The primary reason for failed labeling is often the neglect of its chemical properties. Acridine esters are highly sensitive to moisture, pH, and temperature. If stored improperly or the purity of the reagent is insufficient, the active groups are prone to hydrolysis and deactivation. Many users do not check the status of the reagents before use, which directly leads to a decrease in labeling efficiency. It is recommended to choose high-purity, low moisture acridine ester products and strictly follow the requirements of cold chain transportation and dry storage to avoid repeated freezing and thawing or exposure to air. Meanwhile, the labeling reaction needs to be carried out in a weakly alkaline environment to maintain the activity of the amino reaction; Improper pH control may lead to side reactions or precipitation formation.


2, Common Misconceptions and Optimization Strategies in Marking Operations


In practical operation, improper control of reaction conditions is another key factor in labeling failure. The ratio of acridine ester to biomolecules needs to be precisely optimized: excessive use of acridine ester may lead to non-specific binding and increase background noise; Insufficient dosage will result in a lower labeling rate and insufficient signal strength. The reaction time and temperature also need to be strictly controlled. It is common to avoid light for 30-60 minutes at room temperature, but the specific conditions need to be adjusted according to the molecular size. In addition, the purification step is crucial: unreacted acridine esters, if not completely removed, can interfere with subsequent detection.


3, Biomolecular factors and marker system design


The properties of the marked object directly affect the results. The concentration, purity, and activity of proteins or antibodies are prerequisites for success: if the sample contains impurities or amino protectants, they will compete for binding sites; Excessive molecular steric hindrance may also reduce labeling efficiency. Suggest desalination treatment of biomolecules and determination of amino activity before labeling. The selection of buffer solution is equally important: avoid using reagents containing primary amino groups and add stabilizers to prevent aggregation. The entire labeling system should be kept gently stirred to promote uniform reaction, while avoiding the introduction of bubbles or shear forces caused by violent oscillation.


4, Systematic solutions enhance overall efficiency


Systematic methods can significantly improve the labeling effect in response to the above issues. Standardization is required at every stage from reagent preparation to purification validation: using freshly prepared high-purity buffer, controlling reaction volume to maintain concentration stability, and verifying labeling rate through spectroscopy or functional testing. For difficult to label samples, segmented reactions or the addition of catalysts can be attempted. In daily life, standardized operating habits such as wearing gloves to prevent protease contamination and using inert gases to protect reaction systems can also reduce unexpected failures.


Joining Hands with Desheng Technology: Professional Reagents Ensure Accurate Labeling


The success of chemiluminescence labeling cannot be achieved without high-quality reagents and technical support. Hubei Xindesheng Material Technology Co., Ltd. focuses on the field of chemiluminescence, launching high-purity acridine ester series products, strictly controlling water and impurities, ensuring batch consistency, and providing customized labeling services. Our acridine ester reagent has stable activity and is compatible with various biomolecules, helping users achieve efficient labeling quickly. Whether it is the development of diagnostic reagents or scientific research experiments, Desheng Technology provides full technical support with a professional team, solves labeling problems, and improves detection performance. Visit the official website or contact customer service to obtain free samples and technical solutions, so that labeling experiments will no longer fail!